Cabezas portInstallation of small refrigeratorWear and failure of

2023-10-20 12:46:53
632HP195506591energy114

In fact, there are some unique installation skills when installing the cold storage? The cold storage installed according to these skills is often short in both effect and quality, and the specific installation skills of the cold storage will also make some relatively detailed introduction for you in the following article. When installing the cold storage, you should install it from the corner first. Later, according to the height of the cold storage, make a hole in the middle of the insulation board, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Cold storage fault phenomenon: dryer does not operate, compressor line is disconnected, fuse is blown thermal relay acts, high voltage switch acts, compressor is locked, line is falsely connected or loose fault phenomenon: it stops in a short time after drying, ambient temperature is too high, condenser is blockedCabezas port,The startup of the air-cooled refrigerator unit shall depend on whether the rotation direction of the fan is correct. If the forward rotation can be started for operation, the reverse rotation indicates that the power wiring is reversed, and the phase sequence must be replaced before startup. - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, and make U-bend and silica gel outside the storage.Abalak,With the rapid development of modern commerce, the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly, playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?Installation of box and operating device: the design of box shall be reasonable, and the appearance quality shall meet the requirements of beauty and practicality. All buttons,Cabezas portQuotation for installation of fresh-keeping cold storage, electrical switches, etc. shall be reliable safe, long-term cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, old brand, price advantage and quality guarantee! Easy to identify and operate. The indicator light shall be simple and clear. The device and each switch shall be installed on the upper side outside the warehouse door, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device read data and not easy to be damaged, and the height of the bottom edge of the switch box is about mm.Pay attention to the energy saving of the lighting system: the lighting of the cold storage should be considered comprehensively according to the area, height and warehouse temperature of the cold storage on the basis of safety, science and rationality, from the perspective of energy saving and environmental protection. The lighting in the cold storage is concentrated in the working area.


Cabezas portInstallation of small refrigeratorWear and failure of



Compression refrigerator is commonly used, which is mainly composed of compressor, condenser, throttle valve and evaporation pipe. According to the way of evaporation pipe device, it can be divided into direct cooling and indirect cooling. Direct cooling the evaporation pipe is installed in the refrigerated warehouse. When the liquid coolant passes through the evaporation pipe, it will directly absorb the heat in the warehouse and cool down.The overall layout of the unit is reasonable and the color is. The installation structure of each type of unit shall be consistent.Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage, which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope, a reasonable overall layout, saves land and reduces costs.Inspection basis,Install the temporary lighting facilities in the warehouse, install and arrange the construction electrical equipment, and do a good job in rain proof, moisture-proof, anti binding and other safety protection.What should be considered in building a cold storage? In these aspects, food cold storage is a systematic project of artificial refrigeration to ensure food quality and reduce food decay in a low-temperature environment. Refrigeration technology affects the design of food cold storage, meets the needs of refrigeration technology, energy saving and cost reduction. What problems should be considered in the construction of food cold storage?Installation of cold storage, construction of cold storage, fruit preservation cold storage and medical cold storage have stable, safe, reliable and maintenance free performance. The technical level has reached the domestic level and the advanced level of similar international products. If there is a large amount of ice and water, it must be cleaned in time, and it must not be knocked during cleaning, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking,Cabezas portFruit and vegetable cold storage, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.analysis,After being stored in the medical cold storage project, ventilating medical products may also emit some odors. Once these odors are stored in a certain quantity, they will also have a certain impact on other products. Therefore, we must carry out regular ventilation in the process of daily use, so as to effectively reduce the storage time of products. If the medical cold storage project uses row tube refrigeration, the image of frosting may appear after use for a period of time. If we do not defrost in time,Cabezas portWhich is a good refrigerator, it will also affect the effect of. Therefore I hope you must pay attention to defrosting.The suction pressure of fresh-keeping storehouse remains unchanged, and when the exhaust pressure increases, the exhaust temperature increases; If the exhaust pressure remains unchanged, when the suction pressure decreases the exhaust temperature also increases. Both cases are caused by the increase of compression ratio of fresh-keeping warehouse. Too high condensation temperature and exhaust temperature of fresh-keeping warehouse are unfavorable to the operation of compressor, which should be prevented. Too high exhaust temperature will dilute the oil and even carbonize and coke, which will worsen the compressor conditions of the fresh-keeping warehouse.The door of the combined cold storage is not tightly closed. Please adjust the distance between the hinge on the door and the door lock and the storage body.Cabezas port,The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements. - precautions for vertical plate of cold storage: vertical plate displayThe refrigeration of cold storage pays more and more attention to the needs of environmental protection and energy saving. Professional projects include: cold storage installation, installation of cold storage, cold storage construction, fruit fresh-keeping cold storage, medical cold storage and other related businesses. Merchants who hope to have this business please consider the wide scale of warehouse temperature control, the selection and placement of cooling equipment and the description of wind speed field, which are suitable for the cold storage needs of a variety of goods. Equipped with perfect storage temperature active detection, recording and active control equipment.

404 Not Found

404 Not Found


nginx

Related articles

Cabezas portInstallation of small refrigeratorHow to eliminate the oscillation problem

Cabezas portInstallation of small refrigeratorHow to eliminate the oscillation problem

Thermal insulation performance of thermal insulation materials for food cold storage the requirement...

评论列表

881HP198728332
2023-10-20 13:00:51

The manager is nice! Cabezas portInstallation of small refrigerator is also real.

47HP158935852
2023-10-20 13:56:16

It is still affordable to buy things online, Cabezas portInstallation of small refrigerator I signed for two days late, but the things are really good, and the boss is good. The speed of transportation is also very fast.

965HP113924865
2023-10-20 13:49:26

Make an advertisement for you, friends: This Cabezas portInstallation of small refrigerator product is great value.

416HP186602172
2023-10-20 14:18:48

The first online purchase Cabezas portInstallation of small refrigerator. I use my personal experience to tell everyone that your service attitude is very good. The quality of the goods is also very good. I like you!

263HP145816628
2023-10-20 13:47:00

When Cabezas portInstallation of small refrigerator offer discount points for activities, contact me when there are discounts

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。