FlourishingWorking principle of power transformerIntroduction to inspection standards before leaving the factory

2022-04-09 02:24:39

(I) the distance between the external contour of kV and below dry-type transformer and the surrounding guardrail or courtyard wall shall take into account the convenience of transportation and repair of dry-type transformer, and the distance shall not be less than m; At the angle with actual operation,FlourishingWhat are the test items of dry-type transformer, a spacing of more than m shall be reserved; If metal fence is selected, the metal fence shall be grounded and a warning sign shall be hung at a prominent position.The input and output three-phase power lines shall be connected to phase a, phase B and phase C respectively according to the color of yellow, green and red bus duct of transformer terminal board. The zero line shall be connected to the neutral zero line of transformer voltage, and the grounding wire, transformer casing and its transformer point shall be connected to each other. At ordinary times, the ground wire and zero wire are led out by the neutral wire of the transformer. (for example, the transformer box shall be matched with the ground wire mark of the shell and connected with each other). Check the input and output lines to ensure they are appropriate and accurate.Flourishing,Power transformer is indispensable for power stations and substations, but we must pay attention to many problems in the whole process of applying power transformer.Equipped with a temperature controller,FlourishingSC series dry type transformer, platinum thermistor (pt) is placed beside the embedded hole on the top of the low-voltage solenoid coil to test the winding resistance temperature rise of the transformer stop the cooling centrifugal fan, set up common problem alarm, overtemperature alarm and overtemperature tripping effect, so as to test the safety performance of the transformer operation.Helchteren,In the electric field of the winding to the yoke, there must be a strong line breaking component, so that sliding flash charge and discharge may occur at a lower current. In order to better solve this disadvantage, the appearance of the insulating parts between the winding and the iron yoke should be the same as that of the medium horizontal plane of the winding to the iron yoke insulation as far as possible, so as to reduce the electric field component intersecting with the insulating parts.When sampling in bulk gasoline barrels, but not less than barrels. When sampling in batches of small and medium-sized pails or bottles, samples shall be taken according to % of the total number of barrels (bottles).When using the oil sample of the power transformer in operation, it is necessary to add some oil from the oil gate valve at the lower part of the oil tank or the sampling gate valve to release about kg of waste liquid stored at the bottom to clean the oil inlet, and then take the oil sample.


FlourishingWorking principle of power transformerIntroduction to inspection standards before leaving the factory



Connection group structure of dry-type transformerMany people probably don't know much about the power distribution transformer manufacturers. In fact, the transformer can be plugged in for trial operation after careful inspection before capital investment. During the trial operation period, you must pay attention to the following points. Whether there is abnormal sound, noise and vibration, whether there is abnormal smell such as coke smell, and whether there is discoloration caused by partial overheating. Ventilation is good. In addition, we should also pay attention to the following aspects.The tap changer of power transformer shall also have strong insulation. kV off load tap changer is generally insulated from the ground by the produced insulating paper pipe factory.install,In terms of the place of use, dry-type transformers are mostly used in & ldquo; Fireproof and explosion-proof type & rdquo; It is easy to use in large and medium-sized engineering buildings and multi-storey buildings; The oil immersed transformer because of & ldquo; Accident & rdquo; There is likely to be oil or leakage after fire, and most application places leading to fire accidents are easy to choose in large and medium-sized engineering buildings and multi-storey buildings;Method and process of taking oil sample of power transformerNoise pollution control and prevention measures of dry-type transformer


FlourishingWorking principle of power transformerIntroduction to inspection standards before leaving the factory



If the power transformer stops running for more than h (if the allowable time should be reduced when the ambient humidity is & amp; gt; %), it should be insulated before putting into use and accurately measured with a V grounding megger. The insulation resistance from the primary side to the secondary side and the ground should be ^ mfl, the insulation resistance from the secondary side to the ground should be ^ mh and the insulation resistance from the iron core to the ground should be & amp; gt; mfl (note that the grounding device piece should be removed).Product line, a group of overvoltage maintenance high-voltage Arresters (such as ycs active zinc oxide high-voltage arresters) shall be refitted at the working voltage bus duct side of dry-type transformer.The representative mode of connection group of dry-type transformer is: English capital letters indicate the wiring on the primary side (or primary side), and English letters indicate the wiring on the secondary side (or secondary side). Y (or y) is star wiring, and D (or D) is triangular wiring.Flourishing,Protective measures for damping of dry-type transformerThe insulating layer shaft and the connecting articles between the bell jar and the core shall be removed. If it is a hanging bell inspection, the oil shall be pumped into the bottom of the bell jar before the bell jar can be removed.Insulation and heat removal are different. Dry type transformers are generally insulated with epoxy resin,FlourishingTransformer energy, cooled by natural air and large capacity by centrifugal fan. Oil immersed transformers are insulated by insulating oil, insulated by insulating oil in the circulating system inside the transformer, and heat is discharged on the radiator (radiator) of the circulating system inside the transformer.

404 Not Found

404 Not Found


nginx

Related articles

FlourishingWorking principle of power transformerOverview and classification description

FlourishingWorking principle of power transformerOverview and classification description

When leaving the factory, the production and processing are not smooth and the sealing is poor. The...

评论列表

570HP155642700
2022-04-09 11:08:50

One word! ! value! ! ! The service attitude is really good, FlourishingWorking principle of power transformer delivery is fast. The quality of the goods is also quite good. I like it so much, thank you.

717HP127443542
2022-04-09 10:15:35

FlourishingWorking principle of power transformerHow much is it, can I transfer the goods?

709HP180518493
2022-04-09 11:21:24

It’s really a test and waiting. I finally waited for 3 days FlourishingWorking principle of power transformer to arrive, the opening quality is very good

256HP158312377
2022-04-09 10:59:55

When FlourishingWorking principle of power transformer offer discount points for activities, contact me when there are discounts

632HP195506591
2022-04-09 10:07:21

My colleagues like it very much. Come again next time. It's a rare genuine product. FlourishingWorking principle of power transformer I'm very satisfied with it. The boss has a good personality, awesome. Not bad. The quality is good. The speed is also fast. Really good!

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。