IrelandMobile aluminum alloy lifting platformOverall deviation measures
2024-04-24 00:39:50The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.When the normal power supply is cut off, the lighting inside the non fire elevator has no power,Slide elevators are installed inside buildings and are often used parallel to buildings and sidewalksMeasure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.Izyum,Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning,IrelandMobile reclaimer,IrelandSelf propelled aluminum alloy elevator, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.The compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.
Maintenance of elevator hall doors and car doors. Elevator malfunctions usually occur on the elevator hall and car doors,IrelandHousehold small elevator prices, so attention should be paid to the maintenance of the hall and car doors. One is to refuel the fuel on the upper sill of the door and keep it in good condition, so that the elevator will not make unpleasant noises during operation and the opening of the door. Pay attention to the inspection of the safety contact plate or light curtain type contact plate switch wire of the elevator, as the frequency of opening and closing the door in the elevator is high, which can cause damage to the switch wire. This requires maintenance personnel to inspect it every time they work, and replace it in advance to avoid users having doubts about the quality of the elevator product due to door issues.The elevator suddenly opens the door and does not move after leveling, but automatically resumes operation after a few minutes: The elevator (escalator) has been running for too long, and the motor overheats. To prevent burning out, the motor cools down and automatically resumes operation.The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Quality Assurance,Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.The speed limiter tensioning device and the steel belt tensioning device should be equipped with a safety switch.
To implement the arrangement of escalators and provide feedback, in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.Total quality assurance,Attention: The elevator consists of two main parts: mechanical and electrical. If the elevator is not maintained on a daily basis, its safety cannot be guaranteed. If the elevator needs to be refueled without refueling, it will cause wear and tear on the mechanical components of the elevator, greatly shortening its service life and preventing normal use of the elevator.Passengers wearing long skirts and strapping sandals when riding on the escalator should try to stand slightly in the middle of the escalator to prevent shoes and clothing from being drawn into the escalator and causing danger, and to prevent skirts or pants from getting stuck.Restore the command button function in the cabin for firefighters to operate.Ireland,Brick concrete structure elevator shaft: For unfinished brick structure shafts, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator, and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degreesMeasure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.