Metal oxide arresterRefrigeration equipment for medical cold storageAnalysis of the working principle of
2022-09-04 00:15:20We should implement regular maintenance and daily maintenance, professional cold storage installation, installation of cold storage cold storage construction, fruit preservation cold storage, medical cold storage large quantity, excellent quality and low price, fire resistance - Waterproof - high temperature resistance, strong and durable, and maintain the operation rate of the compressor.The volume of the controlled atmosphere warehouse the size of the controlled atmosphere warehouse shall be calculated according to the volume occupied by the storage products stacked in the controlled atmosphere warehouse, plus the aisle between rows, the space between the stack and the wall and ceiling, and the gap between the packaging. After determining the capacity the length and temperature of the controlled atmosphere warehouse shall be determined. The design of the controlled atmosphere warehouse shall also consider the necessary auxiliary buildings and facilities, such as workshop Packing and sorting room, tool warehouse and loading and unloading platform, so that the quality of controlled atmosphere warehouse can be guaranteed.The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove, and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.market,For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting, dripping, leakage and other conditions of the water supply system exist.Operating the unit: regularly observe the oil level and oil return of the compressor and the cleanliness of the oil. If the oil is dirty or the oil level drops, it shall be solved in time to avoid adverse effects.Whether the parameters of refrigeration equipment are consistent. When the cold storage leaves the factory,Metal oxide arresterCold storage construction and installation company, the temperature and temperature difference parameters of the cold storage shall be customized according to the user's requirements. After understanding the technical parameters of the cold storage, set the parameters on the refrigerator. During use, the air humidity is high and the defrosting interval is long. The common cold storage boards of cold storage include mm, mm, mm, mm and mm polyurethane thermal insulation boards, stainless steel plates, salt thick steel plates, embossed aluminum plates, polyurethane spraying, more general color steel tiles are produced and processed into hidden grooves, which have light weight, high compressive strength, good fire resistance, corrosion resistance and aging resistance, The cold storage board is simple and convenient to assemble, and is a wide range of raw materials selected for the heat insulation and heat preservation of the cold storage. The cost of stainless steel plate and salt plate increases, and it is also easy to deform and damage the appearance.
The cooking materials and foods refrigerated in the quick-frozen warehouse contain a certain amount of fat, protein and starch. The existence of these nutrients will make molds and bacteria multiply and grow in large numbers. In order to do a good job in the hygienic management of cold areas and ensure the refrigeration quality of food and cooking raw materials, it is necessary to carry out the hygienic disinfection of cold areas regularly.Inspection environment,In the process of realizing your dream, you must remove all the influences. It is very important to recognize that when these beautiful refrigerators are built in the villa room, the collection pit (pool) for flushing (thawing) and drainage should adopt the Countermeasures of avoiding freezing and cleaning and avoiding backflow of water.Does the cable wire meet the parameters? In general, the cold storage needs to use phase electricity.Whether there is dirt on the condenser and poor heat dissipation will lead to too high condensation pressure of the refrigerator. In order to protect the compressor, the machine stops running under the action of the pressure controller. When the heat dissipation is good, press the black reset button on the pressure controller, and the machine can automatically resume operation.Metal oxide arrester,Metal oxide arresterHow much is the drug cold storage installation,The drainage at the outlet of the cooling fan, the drainage of the volatile cooler and the road drainage of the refrigerated warehouse storing food or drinks shall not be immediately connected with the sewage and wastewater pipeline system software, but indirect drainage shall be adopted. For the flushing (thawing) water drainage of each layer in the double-layer cold storage, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.In order to prevent damage to the cold storage, it is necessary to lay some foam on the floor of the cold storage tank.The polyurethane insulation board used in the construction of cold storage shall be integral and continuous and there shall be no joint in the middle. The junction of polyurethane insulation board, top plate and ground shall be made into fillet arc for transition, which can well meet the health needs.