Jersey Test items of power transformerFocus on providing new momentum for high-quality development

2022-03-16 01:37:31

Protective measures for damping of dry-type transformerThe bearing capacity of each load is different. Generally, dry-type transformer should operate under rated capacity, while oil transformer has better load working capacity.Jersey ,According to statistics, to occupy the main global technical position, the transformer industry depends on two key data, commodity volume and voltage level. As early as & ldquo; Eleventh Five Year Plan; In the early stage, China has been a powerful country in the production, manufacturing and application of dry-type transformers all over the world, but it is not a big country.The dry-type transformer is composed of two winding resistances, resulting in four wiring groups: & ldquo; y, Y & rdquo;, Y & rdquo;, & ldquo; y D & rdquo; and & ldquo; D, D & rdquo;. In China, only & ldquo; y Y & rdquo; and & ldquo; y, D & rdquo; are selected. Because there are also two types of Y-connection with neutral line and without neutral line. If there is no neutral line, it will not be upgraded. All marks show that with neutral line, it will not be upgraded The letter N after the English letter Y indicates that the neutral line has transformer grounding wire. Yn wiring group, when UAB and UAB overlap,Jersey Impedance standard for dry type transformer, the minute hand points to . & ldquo; & rdquo; in the new wiring group, it is indicated by & ldquo; & rdquo.Mweka,Protective measures for damping of dry-type transformerFault judgment of power transformerWhen the transformer is put into operation, if the tap changer is not in time, a great & ldquo; Tweet & rdquo; The high-voltage fuse is broken when the noise is serious; If the tap changer is defective, it will cause mild & ldquo; Squeak & rdquo; Corona discharge sound, once the load increases, it is likely to burn the circuit breaker of the tap changer. In case of such situation,Jersey Power electronic control, power off immediately for maintenance.


Jersey Test items of power transformerFocus on providing new momentum for high-quality development



The oil in the machinery and equipment of the oil storage tank shall generally stand for more than h before sampling; it is not necessary to stand when sampling on the running power transformer.There is a magnetic induction line crossing in the transformer core, which will cause induced electromotive force on the plan with the magnetic induction line. Because this electric flow creates a closed loop to generate an electric field and forms a vortex, it is called vortex. The existence of vortex makes the transformer core hot and consumes kinetic energy. This kind of loss is called vortex loss.The capacity and working voltage are different. The dry-type transformer is generally suitable for distribution equipment. The capacity is generally below kVA and the working voltage is below KV, which also ensures the rated voltage of kV; Oil immersed transformers are generally suitable for distribution equipment.Quality improvement,The clock expression is used to indicate the phase difference correlation of the working voltage of the secondary side line. The phasor of the working voltage of the primary side line is used as the minute hand, the fixed finger is at o'clock, and the phasor of the phase voltage of the secondary side is used as the second hand.From the appearance, the packaging types are different. The transformer core and electromagnetic coil can be seen immediately for dry-type transformer, and only the shell can be seen for oil immersed transformer;The plastic shells of electrical products and office supplies are equipped with grounding wires. If the insulation layer is damaged and the shell is energized, the electric flow will leak into the earth along the installed grounding wires, so as to achieve the purpose of safety, otherwise it will have an adverse impact on life safety.


Jersey Test items of power transformerFocus on providing new momentum for high-quality development



It is generally made due to unreasonable installation or ineffective sealing. Polymer composite materials can bond metal materials, porcelain, laminated glass and other materials very well, so as to achieve the pressure management of oil leakage.Development Curriculum,(II) the height width ratio of dry-type transformer pier installed on the ground is generally .m, and a guardrail of no less than m shall be installed around it, and a warning sign shall be hung at a prominent position.The transformer manufacturer shall not use hand touch method to detect energized high-voltage equipment, the temperature or temperature rise must be tested by hand. The secondary equipment can be inspected by hand touch method when it is hot and vibrated.Power transformer is one of the key equipment in power station and substation. The function of power transformer is in all aspects. It can not only raise the voltage and send electromagnetic energy to the power consumption area, so as to meet the needs of power consumption. In short, voltage transformation and blood pressure reduction must be carried out by the transformer.Jersey ,The heat discharge pipe of heat pipe radiator is generally made of slotted seamless steel pipe after flattening by stamping die. When the heat discharge pipe is bent and welded by electric welding, it will cause great damage.When the screw of the through core extruder holding the iron core of the transformer is loose causing short circuit obstruction. If not handled properly, there are screw cap parts left on the iron core, or small metal materials fall into the transformer,Jersey Amorphous alloy transformer and oil immersed transformer, the transformer will send out & ldquo; Ding Ding Dang & rdquo; Or & ldquo; Call & hellip; Call & hellip& rdquo; Blowing sound and its & ldquo; Squeak, squeak & rdquo; It's like a magnet sucking a small washer, while the working voltage, current and temperature of the transformer are all normal. Such conditions generally do not endanger all normal operation of the transformer, and can be solved until power failure.

404 Not Found

404 Not Found


nginx

Related articles

Lv LiangHydraulic lifting platform equipmentHow to do daily maintenance and maintenance

Lv LiangHydraulic lifting platform equipmentHow to do daily maintenance and maintenance

Firstly, the maintenance process should be carried out on the premise of ensuring the safety of staf...

BudaHome elevator villa self built houseAnalyze the cause of wall blistering

BudaHome elevator villa self built houseAnalyze the cause of wall blistering

The call button on each floor is no longer working, and the call is cut off.If the elevator is in a...

PingshanHydraulic mobile boarding bridgeVarious methods of use

PingshanHydraulic mobile boarding bridgeVarious methods of use

Secondly, the selection of hydraulic pump stations and oil cylinders for fixed hydraulic boarding br...

BarendhurtHome indoor small elevatorHow to check the accuracy of machining work

BarendhurtHome indoor small elevatorHow to check the accuracy of machining work

and the requirements for cylinder processing and sealing performance are high, the design can achie...

BedgoshHome Outdoor Small ElevatorWhat is the source of

BedgoshHome Outdoor Small ElevatorWhat is the source of

Personalization. Customize personalized home elevators based on the characteristics of the building...

BusiaSmall sightseeing villa home elevatorFrequently encountered failures

BusiaSmall sightseeing villa home elevatorFrequently encountered failures

some elevator users seek temporary workers or unqualified companies for elevator maintenance in ord...

评论列表

409HP184720764
2022-03-16 10:27:16

Your company Jersey Test items of power transformer has a very good service attitude, thank you, and like you.

122HP117294921
2022-03-16 08:41:48

The quality is very good, exactly the same as the seller’s description, very satisfied, really like it, completely exceeding expectations, the delivery speed is very fast, the packaging is very careful and strict, the logistics company’s service attitude is very good, the delivery speed is very fast, and I am very satisfied One time shopping.

717HP127443542
2022-03-16 09:52:49

Dear, Jersey Test items of power transformer I received it, I love it very much, the workmanship is nothing to say, haha, the service attitude is also super good, a very caring seller, I will frequent it in the future.

256HP158312377
2022-03-16 10:15:26

Can you give me Jersey Test items of power transformer detailed specification data?

632HP195506591
2022-03-16 10:13:38

My colleagues like it very much. Come again next time. It's a rare genuine product. Jersey Test items of power transformer I'm very satisfied with it. The boss has a good personality, awesome. Not bad. The quality is good. The speed is also fast. Really good!

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。