Zapotitlan, San FranciscoCold storage installation materialsPrinciple of deformation process
2023-03-07 01:05:51Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage installation, cold storage construction fruit preservation cold storage, old brands, price advantages and guaranteed quality. Polyurethane is a flame retardant self extinguishing material after adding flame retardant. Its softening point can be above degrees Celsius and will only be decomposed at higher temperatures. In addition, the ash formed on the surface of polyurethane will be in its foam, and this ash will help isolate the foam below. It can effectively prevent the spread of fire. Moreover, polyurethane will not produce harmful gas at high temperature.The equipment is built according to the application requirements of low-temperature distribution. It is reflected in the following points: a low-temperature hall, a closed platform, an electric sliding refrigerated door, an anti-collision flexible seal, and a platform height conditioning equipment (lifting channel) are built to complete & ldquo; Door to door & rdquo; Type loading and unloading operation has become a symbol of modern cold storage.Zapotitlan, San Francisco,The machine room shall be equipped with oxygen respirator, gas mask, gas clothing, rubber gloves, wooden stopper, pipe clamp, acid beverage and other necessary protective and rescue articles, which shall be set in a convenient location, managed by a specially assigned person and used regularly. Relevant personnel shall skillfully master the use of oxygen respirator and personnel rescue.No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.San-Jose-de-Ocoa,Danfoss thermal valve is adopted for the thermal valve of the cold storage, with guaranteed quality; Due to the high temperature requirements of the cold storage and the high degree of automation and regulation of the temperature, the temperature system of the cold storage adopts microcomputer full-automatic, does not need special people to operate, and can be remotely controlled. When the temperature exceeds the specified range, it will automatically alarm, which is of great significance to the proper preservation of the cold storage.General quick-frozen warehouses are mostly cooled by refrigeration mechanism with low gasification temperature (ammonia or Freon)The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.
Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, foam holes, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.Whether the warehouse can drill through the wall. The construction and installation of cold storage shall be like the installation of air conditioner, and the external unit shall be connected with the unit in the cold storage.Installation of cold storage, construction of cold storage fruit preservation cold storage and medical cold storage have stable, safe, it must be cleaned in time,Zapotitlan, San FranciscoHow much is a small cold storage, and it must not be knocked during cleaning, so as not to damage the ground and affect the service life of the cold storage.supply,For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate then pour the reinforced concrete (generally at least cm thick), and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.Cold storage is mainly used for frozen processing and storage of food
The door of the combined cold storage is not tightly closed. Please adjust the distance between the hinge on the door and the door lock and the storage body.new product,The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.When adjusting the station, each outlet pipe shall be sawn into a degree inclined mouth to the bottom, and the inlet pipe shall be points of the pipe diameter of the adjusting station.Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Cold storage fault phenomenon: dryer does not operate, compressor line is disconnected, fuse is blown, thermal relay acts, high voltage switch acts, compressor is locked, line is falsely connected or loose fault phenomenon: it stops in a short time after drying, ambient temperature is too high, condenser is blockedZapotitlan, San Francisco,For the ground insulation of large cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate) then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick), and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.Commissioning cold storage. After all parts of the cold storage are installed and connected, the cold storage can be started for cold storage commissioning. According to the needs of customers, adjust the value of the cold storage, the cold storage can reach the predetermined temperature, the cooling speed and the operation of the cold storage are normal, and the cold storage can be delivered for use. The cold storage installation unit shall also provide the cold storage user with training on cold storage use and management knowledge, as well as some after-sales training.In order to prevent damage to the cold storage, it is necessary to lay some foam on the floor of the cold storage tank.