MaesterCataniaWhat to pay attention to when choosing
2023-09-25 09:08:05High lifting height, using side mounted oil cylinders, stable operation, noise free, and longer service life.Model Example: Hanging Cage Specification: LABSC/TDx Type I: ~ Type II: ~ Type V: ~ Technical Requirements: The load-bearing capacity of the foundation should be greater than P: P=(hanging cage weight+outer cage weight+total weight of guide rail frame+counterweight+load) x. (kN).Maester,The pressure joint between the pipe joint and the rubber hose fails prematurely, causing oil leakage or pipe explosion. The oil temperature rises due to frequent action of the overflow valve.The verticality of the guide rail frame should meet the requirements of the specifications.balda The end height of the guide rail frame above the high attachment point should comply with the provisions of the user manual.When the distance between the outer edge of the construction electric elevator and the edge line of the external overhead power line cannot meet the requirements in the table above,MaesterBuster,Maesterdad, effective protective measures should be taken.Mechanical devices controlled by cage movement should not be used to open or close the landing door.
The landing door should meet the requirements of the specifications and achieve standardization.The usual operation of landing and docking.It is reported that a fixed electric elevator has good lifting stability and can only be used for fixed operations, making high-altitude operations easierQuality assurance,MaesterAjaccho,Manual pump: When the system malfunctions, the manual pump can be operated to pump high-pressure oil to raise the car to the nearest floor positionThe bearing capacity of the building structure at the attachment point of the wall bracket should meet the requirements specified in the user manual for construction electric elevators.When the horizontal distance between the edge of the cage and the edge of the landing or between the cage and the landing door is greater than mm and there is no effective protection from other structures, the side protection device for the landing entrance should be equipped.
The wall bracket of the construction electric elevator should be intact and reliably fixed, and its attachment distance, wall bracket spacing, and end height must comply with the requirements of the 'User Manual'. The angle between the plane of the wall bracket and the normal direction of the attachment surface should not exceed degrees;. When the attachment device does not meet the requirements of the 'User Manual' due to conditions, its calculation sheet, design, and production materials should be confirmed by the manufacturer or reviewed by the technical leader of the installation unit, and verified by experts.offer,When the door is closed, except for the gap between the lower part of the door that should not exceed mm, any through-hole and opening size related to the distance between any door and adjacent moving parts, should comply with the provisions of Table of GB -.The safety overtravel of limit switches and upper limit switches should comply with regulatory requirements.Use floor doors and cage door devices on construction sites where conditions permit.MaesterSetting requirements: The landing door should be standardized and tooled.Setting requirements: The foundation and foundation of the construction electric elevator should meet the requirements of the user manual. Before installing the construction electric elevator, the foundation should be inspected and accepted according to the requirements of the specifications. Only after passing the inspection can the installation be carried out.The counterweight guide rail should meet the specification requirements.