Lv LiangSmall sightseeing villa home elevatorTalking about the working organization

2023-08-02 19:00:24

If the elevator is in a downward direction, immediately close the door and return to the first floor station, and automatically open the elevator door.Cleaning and cleaning of elevator car guide shoes. As is well known, the guide shoe runs on the guide rail, and there is an oil cup on the guide shoe. To ensure that the elevator does not make any noise during operation, it is necessary to regularly refuel the oil cup and clean the guide shoe, and the cabin should be cleaned thoroughly.Lv Liang,Passengers wearing long skirts and strapping sandals when riding on the escalator should try to stand slightly in the middle of the escalator to prevent shoes and clothing from being drawn into the escalator and causing danger, and to prevent skirts or pants from getting stuck.The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.Kamiti,Electrical components are roughly divided into screens, electrical switches for each safety circuit, etc. It is the brain of the elevator and the central nervous system of the elevator. The movement, operation, and door opening and closing of the elevator are all controlled by it, so it must be treated as a top priority in daily maintenance work. Do not short circuit the elevator circuit inside the screen during work. When the elevator door system malfunctions, someone shorts the elevator door for convenience in order to find the fault. This is very dangerous, and there are many accidents when shorting the door. Why? If a person opens the hall door and extends their head inward, the elevator happens to run up or down to this point, and the hall door is shorted, the elevator cannot stop, so an accident is highly likely to occur. So in our daily maintenance work, we must not short-circuit the safety circuit. If it is necessary to short-circuit,Lv LiangFixed lifting rotating stage, after maintenance or urgent repairs are completed, we must promptly remove the short-circuit wire. Professional household elevator manufacturer, with a large quantity and excellent quality at a reasonable price. It is fire-resistant, waterproof, high-temperature resistant, sturdy and durable, safe and reliableThe compensation chain and rope shall not collide with the shaft or other components during the operation of the elevator.The household must make two steel splints above the entrance. The position and size of the clamp plate are determined based on the selected door machine model.


Lv LiangSmall sightseeing villa home elevatorTalking about the working organization



Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.In daily life, elevators are a commonly used tool that brings us a lot of convenience. But how much do you know about the types and safety knowledge of elevators?Measure the beam edge distance between the upper and lower support beams. The measurement is to suspend the line from the upper support point to the ground for positioning, and then measure the horizontal distance from the positioning point to the edge of the lower support beam.Analysis project,Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, or has been completed, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.The beam edge distance is too small: The method of shortening the lower platform is to shorten the total length of the escalator, but note that the range of shortening is very limited, generally not exceeding mm. Generally, the platform cannot be shortened because it contains equipment such as cabinets and motors. Change the angle of the escalator from degrees to degrees  “& rdquo; Elevator shaft: The design conditions are provided by the user to the architectural design department. The architectural design department analyzes whether the on-site pit depth, top floor height, reaction force, as well as which building structures are needed (such as smashing stairs or floors), and develops a renovation construction plan. If it is indeed necessary to change the elevator structure due to civil engineering conditions (such as car size, door opening width, etc.), then consider the non-standard design of the elevator.


Lv LiangSmall sightseeing villa home elevatorTalking about the working organization



During the use of elevators some elevator users seek temporary workers or unqualified companies for elevator maintenance in order to reduce costs and save funds. Once safety issues arise, even the responsible unit cannot be found. If the maintenance is carried out by elevator manufacturers or qualified professional companies, on the one hand, the maintenance technology and quality are guaranteed, and on the other hand, if any problems occur, someone is also responsible.Discount,Lv LiangFixed stage elevator,The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.. Different types of civil engineering traction elevators, screw elevators and hydraulic elevators have different requirements for civil engineering. Common traction elevators require a certain amount of hoistway space, steel structure hoistways, and glass curtain walls to create sightseeing elevators; The depth of the pit should be at least cm or more; Additionally, there are certain requirements for the height of the top floor.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Lv Liang,If the elevator is already on the first floor, immediately open the elevator door and enter the firefighter's dedicated state.For escalators that require intermediate support, it is necessary to determine whether the site has the conditions for adding support, as well as the range of support that can be added the height and load size of the equipment and support platform, and other parameters.The front room of the fire elevator is equipped with indoor fire hydrants.


404 Not Found

404 Not Found


nginx

Related articles

Lv LiangSmall sightseeing villa home elevatorHow to find the location

Lv LiangSmall sightseeing villa home elevatorHow to find the location

Measurement of elevator and escalator shafts (III)The call button on each floor is no longer working...

评论列表

275HP127226562
2023-08-02 19:47:38

It is very comfortable to do business with you. Responsible, serious, Lv LiangSmall sightseeing villa home elevator is also good, I must give you a good comment. Looking forward to the next cooperation, I wish Rijin Doujin!

466HP159575805
2023-08-02 20:24:14

I’ve been too busy lately, the confirmation is late, the quality is good, Lv LiangSmall sightseeing villa home elevator genuine, good quality and cheap, haha.

416HP186602172
2023-08-02 20:57:18

Just paid, when will Lv LiangSmall sightseeing villa home elevator arrive, boss.

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。