SaguarragrandCold storage of drugsIntelligent operation of
2022-10-02 00:29:35The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, long service life and high comprehensive cost performance can reach more than years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.Saguarragrand,Actual factors affecting the increase of exhaust temperature of fresh-keeping warehouse: low intermediate cooling efficiency, or too much scale in the intercooler of fresh-keeping warehouse affects heat exchange, the suction temperature of the later stage must be high, and the exhaust temperature will also increase.The bacterial action of acid disinfectants is mainly to coagulate the protein in the bacteria. Common disinfectants include lactic acid, formalin bleach,SaguarragrandInstallation of household cold storage, etc. Specifically, after the fish comes out of the freezer, clean the frost layer on the evaporating pipe group and keep the storehouse temperature below degrees Celsius. Then, according to the volume of ~ grams per cubic meter volume of the frozen storeroom, the storeroom door is closed tightly with the sprayer, and the blower is started intermittently, which makes the vinegar absorb a lot of fish smell.Kum,Installation of box and operating device: the design of box shall be reasonable, and the appearance quality shall meet the requirements of beauty and practicality. All buttons, electrical switches, etc. shall be reliable, long-term cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, old brand, price advantage and quality guarantee! Easy to identify and operate. The indicator light shall be simple and clear. The device and each switch shall be installed on the upper side outside the warehouse door, which is easy to operate, read data and not easy to be damaged, and shall be reliably fixed. The device box is installed on the door frame plate on the door opening side. The center line of the box overlaps the center line of the door frame plate. The bottom of the box is mm above the ground and is reliably fixed. The lighting lamp and door frame wire switch in the warehouse are installed directly below the device, and the height of the bottom edge of the switch box is about mm.Secondly, since the cooling of the compressor is not continuous, the multi work operation at night can be selected if possible. When working at night, the external temperature is low the cooling water temperature is reduced, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, reduces the power operation of the compressor and achieves the purpose of energy saving.The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, more important is the choice of refrigeration system. For example, at present,SaguarragrandDesign of medical cold storage, the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.
During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.To the purpose of cooling down.Cold storage has strong stability. Polyurethane foam technology makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, under the unfavorable local temperature and humidity conditions, the characteristics of the cold storage still do not separate and fall off from the carrier layer and remain stable under normal conditions.technical service,For cold storage, it is very common in our production and life. Cold storage is very important for food freezing and preservation, but its energy consumption is very large in the use of cold storage. How can we solve this problem?The wide, light and thin walls are made of rigid polyurethane foam at the same time as structural materials, making the whole structure have the advantages of light weight, large span and high load. The thinner polyurethane sandwich plate can meet the relevant provisions on building energy consumption limit, which allows the use of thinner plates during construction and saves building space.The installation of cold storage board is a link of the cold storage installation project. High price cold storage installation of various specifications, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage. Waste merchants, industry, enterprises and power departments are welcome to visit and negotiate! The cold storage body and storage plate include: floor vertical plate and ceiling plate. The installation of storage plates in different directions and precautions are as follows: enter the construction site, verify the construction situation according to the construction drawings, determine the equipment installation position, and then refer to the following specifications.
Requirements for refrigeration equipment in quick freezing warehouse: the strict sealing of quick freezing warehouse is obviously different from that of ordinary quick freezing warehouse. Therefore, how to seal the refrigeration equipment is the key. First of all, all through wall pipelines must be equipped with sleeves, and the main frost flushing and return pipeline outside the warehouse shall be equipped with air filling port to prevent the gas in the warehouse from being pumped out of the warehouse by negative pressure. In addition, due to the good sealing of the quick freezing warehouse, the set fluctuation range of the warehouse temperature should not be too large to prevent excessive positive and negative pressure from damaging the warehouse body.How many?,With the rapid development of modern commerce the original cold storage for the purpose of product storage can no longer meet the rapid, accurate and small batch circulation needs of modern commodities. Therefore, the logistics center cold storage cold chain for the purpose of product distribution came into being and developed rapidly, playing a more and more important role in the commodity circulation chain. What are the characteristics of the rapid development of cold storage construction?Air conditioning monitoring pan geographic air conditioning room monitoring system consists of front-end equipment, client / device app and PC large screen.The quick freezing storehouse of vegetables and fruits is not suitable to use exhaust cooling, but use fan to supply air for refrigeration, because the gas in the quick freezing storehouse needs to be circulated and dispersed regularly to avoid carbon oxide poisoning caused by high concentration of carbon oxide in local areas. Therefore, in the quick freezing warehouse, the refrigeration equipment needs to be used together with the air conditioning equipment. The selection of refrigeration equipment is different from that of low-temperature freezer and ordinary quick freezing warehouse.Saguarragrand, which is mainly composed of compressor, condenser, throttle valve and evaporation pipe. According to the way of evaporation pipe device, it can be divided into direct cooling and indirect cooling. Direct cooling the evaporation pipe is installed in the refrigerated warehouse. When the liquid coolant passes through the evaporation pipe, it will directly absorb the heat in the warehouse and cool down.During the early operation of the refrigeration unit, carefully observe the oil return of the compressor and keep it clean. If it is found that the oil level is not clean enough or the oil level drops, replace it with new oil in time, so as to avoid bad compressor and reduce the service life of the compressor.The wide, light and thin walls are made of rigid polyurethane foam at the same time as structural materials,SaguarragrandCold storage installation company, making the whole structure have the advantages of light weight, large span and high load. The thinner polyurethane sandwich plate can meet the relevant provisions on building energy consumption limit, which allows the use of thinner plates during construction and saves building space.