UdenCurved arm lifting platformReasonable price guidelines
2024-01-03 00:00:08How to maintain and maintain the stage? When using the lifting stage in daily life, attention should be paid to maintenance to extend its lifespan. Below, Jinan Dasheng Hydraulic Machinery will introduce several maintenance and attention points for everyone: the brakes of each mechanism should be regularly inspected and adjusted for the clearance between the brake pads and wheels to ensure flexibility and reliability. On the friction surface there should be no dirt present, and any dirt must be washed off with gasoline or thinner. Pay attention to checking each steel wire rope for broken wires and loose strands. If it exceeds the relevant regulations, it must be replaced immediately. Professional elevator manufacturers have a complete range of products, which are popular both domestically and internationally. Our equipment has a long service life! The industry leader in product wire products,Heavy load capacity: protective plate form: ° Or ° Interchangeable configuration rocker working angle: ° Drive method: hydraulic power unit drive or screw drive.Check the wear condition of the pinion and rack, please refer to the instruction manual for specific requirementsSunan,The wear rate is fast, and due to factors such as processing, assembly, and adjustment of new machine components, the friction surface is rough, the mating surface area is small, and the surface pressure condition is uneven. During the operation of the machine, the concave and convex parts on the surface of the parts are intertwined and rubbed against each other. The metal debris that falls off from the grinding process, in turn,UdenTrailer folding arm lifting platform, acts as abrasive and continues to participate in friction, further accelerating the wear of the mating surface of the parts. Therefore, during the running-in period, it is easy to cause wear on components (especially the mating surface), with a fast wear rate. At this point, if overloaded, it may cause damage to the components and lead to early failures.Many times, after installing hydraulic cargo elevators in factories, floors, docks and other places,UdenOblique hanging obstacle free lifting platform, there may be some adverse reactions and problems in the early stage. Below, Yakali's editor summarizes some common problems with hydraulic cargo elevators and provides some statements on how to solve and prevent these problems.Check if the orientation of the upper and lower limit blocks on the guide rail frame is correct
When installing, disassembling and adjusting the rotating mechanism, it is important to ensure that the centerline of the reducer of the rotating mechanism is parallel to the centerline of the gear, and its meshing surface is not less than %. The meshing clearance should be suitable for each box, distribution box, and should be kept clean regularly. Dust on electrical equipment should be cleaned in a timely manner. When encountering overheating in the electric motor, it is necessary to stop it in a timely manner and troubleshoot before continuing to operate. The motor bearings should be in good condition,UdenMobile boarding bridge price, and the hydraulic cargo elevator should provide us with safety protection. The application of hydraulic cargo elevators in our production is already very common, and plays an important role in our production, especially in high-altitude operation of goods.Vibration aging treatment and effect judgment: According to the aging process plan, after setting the support points and vibration pickup points of the workpiece, use a rigid fixture to fix the exciter on the workpiece, so the excitation force is selected as the fourth gear.Use a feeler gauge to check the wear condition of the worm gear of the worm gear reducer. Please refer to the instruction manual for specific requirementsdemand, it should be adjusted in the opposite direction; When the meshing backlash of the gear pair is greater than .mm, loosen the connecting nut of the eccentric shaft of the guide roller and the tooth back pressure wheel as shown in , adjust the tooth back pressure wheel to press towards the back plane of the gear rack until the backlash reaches a reasonable range. Otherwise, it should be adjusted in the opposite direction. At this point, the guide roller should be loosened for o and then adjusted according to the adjustment of the guide roller.The surface of each part of the brush should be kept clean, and the brush pressure should be adjusted to ensure that its area is not less than %.The reduction gearbox, gearbox, external meshing gear and other parts, as well as the hydraulic oil, are all carried out according to the requirements in the table.
Check all standard sections and diagonal support connection points. Check the fastening bolts of the gear rack and ensure that the motor cooling wing plate and organization are cleanOnline consultation,Check the wear and clearance condition of the guide wheel of the cargo elevatorVibration aging treatment and effect judgment: According to the aging process plan, after setting the support points and vibration pickup points of the workpiece, use a rigid fixture to fix the exciter on the workpiece, and use the manual function of the equipment to test the vibration. It is determined that around revolutions is the resonance frequency of the component. The amplitude generated by the eccentric gear of the exciter in the fourth gear can meet the vibration processing requirements of the foundation seat, so the excitation force is selected as the fourth gear.Please refer to the instruction manual for the maintenance and maintenance of the elevator to check the braking torque of the brakeUdenDrop test to check if the braking interval of the safety governor meets the requirements of the rules. Equipment transfer maintenance: Check the coupling between the electric motor and the worm gear reducer, and dismantle the gearbox. Clean all components and seals, replace excessively worn and deformed parts and smooth oilAll connecting shafts must have split pins and be sufficient.Check and repair the electrical circuit and control panel switch components. If there is aging in the circuit, replace it