IsalkoCold storage design and installationThe industry has entered a new mode of quality assurance alliance
2022-12-20 00:14:01Other aspects: in the design process of food cold storage, it is also necessary to consider the cooperation between the cold storage and on-site fire fighting, ventilation, science and environmental protection. When designing and installing the cold storage, the drainage problem must be considered, and the following points should be paid attention to during redesign and installation.For water-cooled units, the turbidity of cooling water shall be frequently, the cooling water shall be replaced frequently, and whether the running, emitting, dripping, leakage and other conditions of the water supply system exist.Isalko,Mark the name on each filter.Cold storage construction: which one is suitable for you? Which one is suitable for you?Mary,Cork board: cork board can be said to be a relatively primitive kind of cold storage. The thermal conductivity of cork board is relatively low, and it is easy to obtain so it is not difficult to process, so it is generally used as the insulation board in some ordinary cold storage. If you want to pursue better thermal insulation performance, you have to look at the following materials.On the basis of cold storage and preservation, the quick-frozen warehouse increases the regulation of gas composition, inhibits the respiration of fruits and vegetables, delays their metabolic process, better maintains the freshness and commercial quality of fruits and vegetables, and prolongs the storage period and shelf life of fruits and vegetables. Generally, controlled atmosphere storage of fruits can prolong the storage period by & mdash; Three times or more. OK, what is the standard of quick freezing warehouse?Regular oil discharge, descaling and air discharge: when there is a .mm thick oil film in the evaporator coil, the evaporation temperature will decrease by ℃ and the power consumption will increase by more than ; When the scale on the water pipe wall in the condenser reaches mm, the condensation temperature will rise by ℃ compared with the original temperature, and the power consumption will increase. When the refrigeration system is mixed with non condensable gas and its partial pressure reaches .mpa, the power consumption will increase by about . It can be seen that it is cold
The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, or stops before the storage temperature reaches.The exhaust temperature of fresh-keeping storehouse is directly proportional to the compression ratio and suction temperature. If the suction superheat temperature of the fresh-keeping warehouse is high and the compression ratio is large,IsalkoCold storage installation Cold Storage, the exhaust temperature is also high. If the suction pressure and temperature remain unchanged, when the exhaust pressure increases, the exhaust temperature also increases. - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance,IsalkoCold storage board installation, and make U-bend and silica gel outside the storage.Packaging strategy,With the development of the times, refrigeration devices are becoming more and more common. All aspects of life are inseparable from its use. Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, it is important to select materials with good thermal insulation. Cold storage is a better material selection, and manufacturers need to grasp its key points in the production process of cold storage.During the use of the goods yard medical cold storage project, the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.
- precautions for floor installation of cold storage: the floor shall be installed flat, the uneven part shall be leveled with materials, and the locking hook between the plates shall be locked to ensure that the warehouse surface is flat without hollow feeling. (note that if this drainage system is installed outdoors in the north, the drainage pipe shall be insulated).quality standard,For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking then lay the XPS extruded plate (staggered laying is required when laying the extruded plate),IsalkoHow much is the installation of fruit cold storage, then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick), the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.The maintenance of electrical equipment in the wholesale of fresh-keeping warehouse equipment is actually operated by welders or staff who understand the knowledge of power consumption. The switching power supply must be disconnected during maintenance.Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; gt; mm; The electrical box can be fixed on the building wall or on the angle steel frame.Isalko,Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage it is very important to select materials with good thermal insulation. Cold storage is a better material selection, and in the production process of cold storage, there will be no condensation in the cold storage of the plant. Condensation inside the cold storage or inside the insulation layer is harmful. Irreversible damage or deformation occurs in the new external insulation, and the external surface temperature of the external wall changes sharply. For example, the insulation and sound insulation effects of polyurethane insulation board are relatively good, which can be used in many industries. As we all know, the cold storage will consume more energy during operation, and can not guarantee a good refrigeration effect. The performance of polyurethane insulation board meets the construction requirements of cold storage, so a large number of polyurethane insulation boards need to be used in the construction of general cold storage. Next let's understand the physical properties of polyurethane insulation board.Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.No matter whether the food cold storage or quick-frozen storage is in use, it is inevitable that there will be various small faults. Don't be nervous when there are problems. You can find or eliminate problems according to the knowledge taught today.