KotuiVegetable fresh-keeping cold storage installation companyWhat do you need to know about
2022-11-17 00:13:24The foaming technology of polyurethane with strong stability makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, it can bear various internal and external combined loads such as wind force,KotuiHow much does it cost to install the cold storage, self weight and normal collision, and the insulation layer still does not separate and fall off from the carrier layer and remains stable in the state.The refrigerator compressor unit generally adopts high-end units with guaranteed quality and strong operation stability. The evaporator adopts the imported joint venture refrigeration air-cooled evaporator, which can effectively meet the refrigeration capacity of the refrigerator and ensure the refrigeration effect of the refrigerator. The refrigerator lamp adopts the special LED energy-saving lamp for the refrigerator, which has the advantages of low temperature resistance, low energy consumption and long service time, It can effectively save the operation cost of cold storage.Kotui,Whether it is a fruit fresh-keeping warehouse or other cold storage, there are many details to pay attention to in the transformation of the cold storage. If other small items are not done well, it will bring a lot of trouble to the later use, such as high energy consumption and small problems.Polyurethane spraying is widely used in large and medium-sized refrigerators. Different well-known brands are produced at different prices,KotuiCold storage plant installation, and the product quality is relatively large. However, it is not high-quality or good goods. This is the result of long-term cooperation.Kunka,Whether the water pump works normally and whether the moldy switch is effective. In case of abnormality, timely handle the overhaul and maintenance of the refrigeration compressor in the cold storage: generally, the refrigeration oil and drying filter shall be replaced times after the operation of the cold storage equipment. Replacement after half a year. Depending on the circumstances.Before the acceptance and delivery of the project, the board surface shall be wiped clean. If there is any scratch, it shall be treated. There shall be no obvious scratch on the board surface.There are many application scenarios of cold storage, which are different. For a long time it provides various cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, on-site settlement, honest operation, and has offices all over the country for long-term cooperation. Different purposes, functions and designs, so what needs to be understood in cold storage design?
The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, which can be determined according to its own budget and actual needs. At present, most cold storages adopt single-layer steel structure, and are equipped with combined thermal insulation warehouse body, unloading platform, refrigeration system, system, pipeline system, etc. according to the actual needs of cold storage circulation.The foundation of cold storage is affected by low temperature and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, it may even make the cold storage unusable. Therefore in addition to the thermal insulation layer, the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.Fair price,Moreover polyurethane does not produce harmful gas at high temperature.Floor insulation of small cold storage the structure of small cold storage is usually called surface, that is, the top, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.
Because polyurethane sheet has excellent thermal insulation performance, it can reduce the thickness of building envelope and increase indoor use area under the same thermal insulation requirements.Direct material,Polystyrene foam: polystyrene foam is a new type of synthetic thermal insulation material. It is a kind of plastic, with small density, light weight, strong heat insulation effect and excellent low temperature resistance. However, due to its cold shrinkage,KotuiInstallation of refrigeration warehouse, it is not very convenient for installation.When the valve is opened too large or too small, the fresh-keeping warehouse will lead to too large or too small refrigerant flow, poor valve operation, reduced refrigeration efficiency and even equipment damage.Energy saving and power saving: the design cost of quick freezing warehouse mentioned above is very low, but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, the tightness of the quick freezing warehouse door, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.Kotui,The exhaust temperature of the compressor equipment is often. When the season changes and the temperature difference changes greatly, pay attention to it. If the machine is abnormal, it needs to be checked in time.It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is - degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even in the work, the water temperature is lowFloor insulation of small cold storage the structure of small cold storage is usually called surface, that is, wall and ground are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials, because the loading and unloading of small cold storage is often handled manually rather than forklift. Of course if the height of the warehouse is high and the forklift is required for warehousing, loading and unloading, the insulation board is not recommended for ground insulation, but the ground needs to be insulated separately like the ground insulation sample of medium-sized cold storage.