Darbus Mobile reclaimerA Brief Talk on the Matters Needing Attention in Selection

2024-04-06 01:50:45

The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.Darbus ,In daily life, elevators are a commonly used tool that brings us a lot of convenience. But how much do you know about the types and safety knowledge of elevators?Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Erzincan,The front room of the fire elevator is equipped with Class B fireproof doors or fireproof rolling shutters with stopping function.Measurement of elevator and escalator shafts (III)Measurement of elevator and escalator shafts (III)


Darbus Mobile reclaimerA Brief Talk on the Matters Needing Attention in Selection



The effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.The braking system of the elevator is usually closed, which means it is in the braking state when there is no power,Darbus Fixed lifting stage, and only when it needs to be turned on, the brakes closed and the elevator was braked in mid air. When the elevator descends abnormally, cut off the power and the elevatorMachine room power supply: The power supply should be three-phase V, HZ, and the lighting power supply should be single-phase V, including: home elevator manufacturersInformation recommendation,To implement the arrangement of escalators and provide feedback in order to determine the configuration of certain shared devices, the order of shipment, and the alignment of handrail turns during continuous arrangement.The door closing button has no self maintenance function. During the designated maintenance period, the elevator components in operation are inspected, refueled, dust is removed, and safety devices are debugged. Including non-destructive testing and maintenance of elevator traction steel wire ropes.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, the force on the upper and lower support points will also increase. If the edge distance of the beam increases too long, support needs to be added in the middle of the escalator truss. In addition,Darbus Self walking aluminum alloy lifting platform, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.Installation conditions,Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed, is under construction, or has been completed, it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Overloaded elevators do not operate: The load of elevators is limited, and if they are overweight, they will alarm and generally cannot be started. Most passengers can also voluntarily exit.Measurement of elevator shafts in new construction projects under different on-site conditions: When the building design is not yet completed,Darbus Villa Home Seat Elevator, the operator only needs to provide the user with the standard elevator layout of the required elevator specifications, and the user entrusts the design department to design the elevator shaft. When the architectural design has been completed, and the site has not yet been constructed is under construction, or has been completed it must be determined based on the current construction or measured dimensions. If the original civil design of the shaft needs to be modified, the user should entrust the architectural design department to make the shaft design modification based on the layout provided by the elevator.Darbus ,Measure the length, width, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.Brick concrete structure elevator shaft: For unfinished brick structure shafts, users can be required to make a circle of beams at a certain height, arranged on three sides, and disconnected on one side of the elevator entrance. The distance between the center heights of the beams depends on the product model, and should not exceed mm. The beam height should be mm, and the thickness should be the same as the wall. The lower ring beam is -mm away from the bottom of the pit, and the higher ring beam is -mm away from the lower surface of the shaft roof. The completed framework with a solid brick structure shaft can be equipped with steel plywood at the position of the fixed guide rail support frame. The position and size of the plywood are provided by the elevator and the user is responsible for providing materials and construction. If the shaft structure is made of hollow bricks without ring beams, steel beams can be considered to be added between the frames for rectification.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.


404 Not Found

404 Not Found


nginx

Related articles

Darbus Mobile reclaimerInconsistent views on the industry outlook

Darbus Mobile reclaimerInconsistent views on the industry outlook

Multiple elevator shafts can be connected and an - # I-beam can be fixed at a certain height between...

评论列表

263HP148803710
2024-04-06 10:33:31

It is very comfortable to do business with you. Responsible, serious, Darbus Mobile reclaimer is also good, I must give you a good comment. Looking forward to the next cooperation, I wish Rijin Doujin!

258HP138990173
2024-04-06 09:07:02

It’s really a test and waiting. I finally waited for 3 days Darbus Mobile reclaimer to arrive, the opening quality is very good

275HP127226562
2024-04-06 10:39:16

The logistics is very fast, look forward to working together again

323HP155335083
2024-04-06 10:04:33

Darbus Mobile reclaimer Very good, I will order yours for the next batch.

35HP162657470
2024-04-06 09:54:34

Darbus Mobile reclaimer Very good, good quality and low price, express delivery is also fast, and inspection is also very standard.

发表评论    

◎欢迎参与讨论,请在这里发表您的看法、交流您的观点。