KanasDistribution transformer procurementWhat to do if it breaks, how to fix it
2022-05-02 12:00:33For no-load impulse closing of transformer, pay attention to the following matters:The scientific research of power transformer oil is generally carried out according to the way of sampling. What are the common sampling methods and processes?Kanas,What is the cause of power transformer core failure?() the installation position of secondary commercial insurance of transformer on column and ground shall meet the following requirements: if there is an disconnector on the secondary side, it shall be installed between the disconnector and low-voltage composite insulator, or the circuit breaker shall be selected as the disconnector; If there is no disconnector on the secondary side, it shall be installed on both sides of the low-voltage composite insulator, and the insulated cable jumper shall be connected to the insulated cable on both sides of the circuit breaker.Music,Deterioration damage of transformer core insulationUse fiber materials to seal the bolts to achieve the goal of controlling leakage. The other is to screw out the bolt (nut), wipe the Fushi blue film remover on the surface, and then tighten it after wiping the raw materials on the surface. After drying, the treatment goal can be achieved.In relay protection dry-type transformer the disconnection of the fault point is related to each other. In a word, if there is any problem at a certain point, it will affect the whole power circuit
Oil leakage of heat pipe radiatorOil sample inspection & mdash; & mdash; the performance parameters such as compression resistance and residue shall be carried out every three years. The long-term overload or overload of the transformer can reduce the cycle time.Causes of fire in power transformersupply,KanasImpedance standard for dry type transformer,KanasOil immersed transformer 1250,The switching power supply lacks one phase of power;It will also produce many faults, effectively deal with various faults of oil immersed transformer, make full use of the performance indicators and advantages of oil immersed transformer, and continuously improve the safety factor of oil immersed transformer. Ignition is a common fault of oil immersed transformer. The key fault of oil immersed transformer is short-circuit fault, and short-circuit fault is more general.Power transformer plant
The vibration reduction solution of cable bridge is to modify the hard connection between bus bridge and dry-type transformer, and the vibration reduction solution is made at the cable bridge.Product line,KanasPower transformer system,The tail end of the high-voltage winding head and the middle tap are made of copper inserts and embedded parts, with good strength and stiffness, which is conducive to adjusting the data and has a unique and neat style.Power saving analysis of transformerNoise solution of dry-type transformerKanas,What is the wiring mode of dry-type transformer?Avoid the load operation of power transformer: if the load operation is long-term, it will lead to the scalding of solenoid coil, slow aging of insulation, short circuit fault between boxes, two-color short circuit fault or short circuit to ground fault and dissolution of oil.Plug in the power with full load first observe and detect that the input and output voltage meets the regulations. At the same time, ignition, odor and other abnormal conditions. If there is any abnormality