QuebecInstallation price of refrigeration warehouseComposition and function of
2022-04-24 02:28:12It is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is - degrees. If our humidifier is connected with the warehouse, there is no temperature compensation, even in the work, the water temperature is lowIt is equipped with temperature compensation to automatically adjust the water temperature. The water temperature of ultrasonic atomization is - degrees. If our humidifier is connected with the warehouse, there is no temperature compensation even in the work, the water temperature is lowQuebec, and the microcomputer system is adopted, and the temperature can be adjusted at will; The seafood machine unit has compact structure and stable performance. Users only need to connect the power supply and the cooling water pipeline to put it into operation; The wholesale seafood machine condenser in the fresh-keeping warehouse adopts internally threaded copper pipe. Good heat exchange effect; The seafood machine adopts pure titanium tube evaporator, which has good cooling effect and strong performance; The seafood machine unit wholesale in the fresh-keeping warehouse has extraordinary pressure sealing test, and the performance of each component is particularly good; The seafood machine unit has the advantages of low noise, low vibration,QuebecCharge for cold storage, fast cooling, long service life, multiple quality protection devices, high cost performance and good quality. The seafood machine can be customized according to customer requirements; Many fruit wholesalers will transform the original warehouse into a fruit preservation warehouse in order to store fruits for a longer time. Due to the huge difference between warehouses, it needs a lot of attention to transform the warehouse into a qualified energy-saving fruit preservation warehouse.Suggestions on the quantity of polyurethane cold storage insulation materials: cold storage investment is a long-term and profitable investment. A high quantity of hair can certainly reduce the initial investment, but it is necessary to grasp a certain limit and comprehensively consider the long-term energy consumption and initial investment, it is usually recommended that the number of thermostat refrigeratory outlets should be ~ square / ton.Henzada,During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage and other special products, old brands, price advantages and guaranteed quality. Polyurethane is a flame retardant self extinguishing material after adding flame retardant. Its softening point can be above degrees Celsius and will only be decomposed at higher temperatures. In addition,QuebecInstallation of second-hand cold storage, the ash formed on the surface of polyurethane will be in its foam, and this ash will help isolate the foam below. It can effectively prevent the spread of fire. Moreover, polyurethane will not produce harmful gas at high temperature.The spacing of pull rivets at inner and outer corners is mm and mm respectively; After the polystyrene library is installed, the wall panel joints shall be evenly sealed and decorated with silicone sealant.
Step of cold storage design: define the volume of the cold storage warehouse. The size of the cold storage should be based on the design of a large number of agricultural products to be stored for a long time. This volume is calculated based on the essential volume of stored goods accumulated in the cold storage, plus the row to row corridors, the indoor space between the pile and the wall, the ceiling and the gap of the packaging house. After the volume of the cold storage is determined, the length and height width ratio of the cold storage shall be determined. Necessary auxiliary engineering buildings and equipment shall also be considered in the design of cold storage, such as working intermediate, packaging and combing room special tool warehouse, loading and unloading platform, etc.The selection of wires shall have a safety factor, and the temperature of the wire surface shall not exceed ℃ during unit operation or defrosting.Generally, in the actual operation of the refrigeration system because the temperature conditions are constantly changing, only by relying on the careful operation of the cold storage management personnel and accurately adjusting the operation of the refrigeration equipment of the cold storage, can the refrigeration system always be in the ideal working state and achieve the effect of energy saving.Quality department,Cold storage design steps: selection and preparation of cold storage location. According to the application characteristics, cold storage can be divided into sexual cold storage, retail cold storage and large-scale cold storage. When large-scale cold storage starts to build a planting area with more centralized hand supply factors such as superior geographical location and contact with the market should also be taken into account. The cold storage should be located in a cool place without sunlight and frequent warm air. Small and medium-sized cold storage should be built in the room. cold storageEstablish a perfect computer network, and achieve the traceability of food safety. In the European Union, the United States and Japan, all members of the food supply chain have the legal responsibility to implement traceability. - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate, and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance, and make U-bend and silica gel outside the storage.
The foaming technology of polyurethane with strong stability makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is, under the unfavorable local temperature and humidity conditions,QuebecFresh storage installation Telephone, it can bear various internal and external combined loads such as wind force, self weight and normal collision, and the insulation layer still does not separate and fall off from the carrier layer and remains stable in the state.original,Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than ℃, and it will decompose only at higher temperature. In addition, which helps to isolate the foam below. It can effectively prevent flame spread.The air suction surface of the condenser shall be kept more than mm away from the wall, and the air outlet shall be kept more than m away from obstacles.During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.Quebec,Immediate cooling is to install the condenser of the cold storage in the box or building of the cooling equipment, use the volatilization of the refrigerant to immediately cool the air in the air, and use the cold air to cool the objects that need to be cooled. This kind of refrigeration is characterized by faster cooling speed, small heat conduction temperature difference and simple system software, so it is widely used.No matter whether the food cold storage or quick-frozen storage is in use, which has excellent thermal insulation performance, storage and circulation effect and reduces operation energy consumption. Of course, more important is the choice of refrigeration system. For example, at present, the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.